Warning Zone - Omron F3SG-SRB Series User Manual

Hide thumbs Also See for F3SG-SRB Series:
Table of Contents

Advertisement

Setting with SD Manager 3

4-3-4-6. Warning Zone

First, carry out 4-3-1. Preparing to Change Settings.
Next, click the icon below on the Top page.
The setting screen below is displayed.
No.
Function name
1
Warning Zone
2
Setting by
3
Zone setting
4
Confirm zone
For more information on warning zone, refer to 2-18. Warning Zone.
If using this function together with other functions, make settings taking the condition of adjacent zones into account.
For more information on zone adjacency conditions, refer to 2-19. Setting Zone Adjacency Conditions.
When changing the settings is complete, confirm the settings and write the configuration to the F3SG-SR.
To enable the written configuration, refer to 4-2-7-3. Writing Configuration into Intelligent Tap.
When connecting the Intelligent Tap to a F3SG-SR and trying to return the F3SG-SR to [Detecting], follow step 4 of
4-1-3-2. Connection Procedure When Using USB Connector to restart the F3SG-SR and Intelligent Tap, or click the
[Monitor]
F3SG-SR
214
User's Manual
Description
Select Enable or Disable for the Warning Zone function.
When you want to restore the readout settings received from
the F3SG-SR, click [Recover status at readout].
Select either manual setup using SD Manager 3 or setup by
teach-in.
To configure zone settings, specify desired bottom and top
beam numbers from the drop-down list, or directly on the
chart. When you check the [Designate from chart] box, you
can specify a zone range by dragging red lines shown on the
chart. In both cases above, execute [Confirm zone] to confirm
the settings.
Confirm the settings of the zone.
button.
Configurable value or
Initial value
numerical range
Disable
Disable/Enable from
upper/Enable from
lower
Manual
Manual/Teach-in
-
Desired beam (in 1-
beam increments)
-
-

Advertisement