4-1-3-3. Connection Procedure When Using Bluetooth

(F39-SGBT)
When pairing your device with the F39-SGBT Bluetooth® Communication Unit, make
sure that the model name and serial number of the sensor to be configured match the
information on your device.
Do not use the F39-SGBT Bluetooth
equipment such as a pacemaker. Radio wave may affect the operation of such
equipment.
1.
When you change the settings by using SD Manager 3, turn Positions 1 and 2 as shown below.
• Position 1: ON (Lock)
1
O
N
2
• Position 2: OFF (DIP Switch Disabled)
3
4
5
6
7
8
: Indicates the switch position.
2.
Connect the Bluetooth
For the details of the Bluetooth
Unit F39-SGBT Manual."
The configuration changed by SD Manager 3 is saved in the internal memories of the Intelligent Tap and F3SG-SR.
If the Position 2 of the DIP Switch on the Intelligent Tap is turned ON (DIP Switch Enabled) after configuration is
changed, the tap operates based on the setting of the DIP Switch. If the Position 2 of the DIP Switch is turned OFF (DIP
Switch Disabled) again, the tap operates based on the configuration memorized in its internal memory.
The configuration data of the Intelligent Tap can be read out even if Position 2 of the DIP Switch is ON (DIP Switch
Enabled).
®
Communication Unit in close proximity to medical
®
communication unit with the Intelligent Tap as follows.
®
communication unit, refer to "F3SG-SR Series Supported Bluetooth
Setting with SD Manager 3
®