System Operation and Functions
The user can make changes to the settings by the SD Manager 3.
Load switching frequency threshold
2-26-6. Muting Statistics Information
This function logs and visualizes conditions of the F3SG-SR muting operations to help the user adjust
settings of muting input time difference. Also, its statistic calculation allows for optimal settings with
reduced test runs.
Refer to Chapter 4 Setting with SD Manager 3 for more information on using this function by the SD Manager 3 or SD
Manager 3 Mobile APP.
2-26-7. Intelligent Tap Log
You can use the SD Manager 3 to read the maintenance information (Error Log / Accumulated power-
on time) of the Intelligent Tap to view on a PC screen. The Maintenance Information function indicates
the following information:
• Error Log
The user can view details of errors occurred in the past. The error information is recorded in the
Intelligent Tap at the time of occurrence of an error. The displayed information is useful for
troubleshooting. Up to 50 past errors can be recorded.
• Accumulated power-on time
The user can view an accumulated value of power-on time from when the Intelligent Tap is powered on
for the first time after purchase until the present. It is not possible to reset this value by the power-on
time reset function.
F3SG-SR
122
User's Manual
Function
100,000 times in 1-time increment 100,000 to 4,000,000 times in 1-time increments/
Initial value
Configurable value or numerical range
Disable