System Operation and Functions
Information (Output operation mode) assigned to auxiliary output
Information Name
Safety output information
Interlock information
Lockout information
Excess power-on time
information
Excess load switching
frequency information
Stable-state information
Muting information
Override information
Muting/Override information
Light level diagnosis
information
Warning Zone Information
PSDI Information
Blanking bream unblocked
information
Troubleshooting support
signal
Designated beam output
information
Sequence error information
Reset-input information
Mute A input information
Mute B input information
EDM input information
Individual cascaded sensor
output (Channel 1)
Individual cascaded sensor
output (Channel 2)
Individual cascaded sensor
output (Channel 3)
Blanking/Warning-zone
information
Instantaneous block
information
Pre-reset Information
Communication quality
diagnosis information
Recoverable error information Assigned when a recoverable error occurs.
Replacement-recommended
error information
No assignment (function OFF) This function is disabled.
It is recommended that the Position 2 of the DIP Switch be set at OFF (DIP Switch Disabled).
Refer to Chapter 4 Setting with SD Manager 3 for more information on setting this function by the SD Manager 3.
F3SG-SR
60
User's Manual
(Auxiliary output is turned ON under the following condition)
When the safety outputs are in the ON state
Under the INTERLOCK state
Under the LOCKOUT state
When power-on time exceeds power-on time threshold
When load switching frequency exceeds load switching frequency threshold
When light intensity, which is constantly monitored, is 170% or higher of ON-threshold
Under the MUTING state
Under the OVERRIDE state
Under either the MUTING or OVERRIDE state
When the F3SG-SR is unblocked and light intensity is within a range from 100% to 170% of
ON-threshold for 10 s or longer
When warning zone is blocked
When the F3SG-SR is ready to be blocked for feeding or removing parts
When Fixed-Blanking or Floating Blanking beams are unblocked
When one of the signals of Sequence error information, Interference/vibration information and
Light level diagnosis information is in the ON state.
When a designated beam is blocked or unblocked
Under the MUTING SEQUENCE ERROR state or the INTERLOCK SEQUENCE ERROR
state
When RESET/EDM/Override input is in the ON state
When MUTE A input is in the ON state
When MUTE B input is in the ON state
When EDM signal input is in the ON state
When the safety outputs of the primary sensor in cascade connection are in the ON state
When the safety outputs of the 1st secondary sensor in cascade connection are in the ON
state
When the safety outputs of the 2nd secondary sensor in cascade connection are in the ON
state
When Fixed Blanking, Floating Blanking, Reduced Resolution or Warning Zone function is
enabled
When the F3SG-SR system stops accidentally due to interference or vibration. (In case of
cascade connection, when any of cascaded segments comes under this condition.)
Under Pre-reset state
Assigned when retry occurs in communications due to noise or short-circuit of the
communication line.
Assigned when a replacement-recommended error occurs.
Description