Index
Sub-Index
70
1
Synchronization
method setting
2
External device
monitor setting
3
Interlock / Pre-
Reset / PSDI
setting
4
Blanking setting
5
PNP / NPN setting
6
Dip switch setting
7
Muting status
8
Override status
9
Muting sequence
error status
10
Safety output status
11
Blanking bream
unblocked
information
12
Push switch status
71
0
Receiving light level
(Primary
sensor
Receiver)
72
0
Receiving light level
(Secondary
sensor 1
Receiver)
73
0
Receiving light level
(Secondary
sensor 2
Receiver)
80
0
Error code of
Intelligent Tap
Name
R/W
Length
R
1 byte
R
1 byte
R
1 byte
R
1 byte
R
1 byte
R
1 byte
R
1 byte
R
1 byte
R
1 byte
R
1 byte
R
1 byte
R
1 byte
R
232 bytes 1byte x 232 beams
R
232 bytes 1byte x 232 beams
R
232 bytes 1byte x 232 beams
R
48 bytes
(8 bytes
x 6)
Setting with Intelligent Tap
Setting contents
0: Optical sync. Scan code A
1: Optical sync. Scan code B
2: Wired sync.
3: Reserved.
1: Enable , 0: Disable
0: Auto reset (both start and re-start interlock are disabled)
1: Start interlock is enabled.
2: Re-start interlock is enabled.
3: Manual reset (both start and re-start interlock are
enabled)
4: Pre-Reset is enabled.
5: PSDI single break
6: PSDI double break
The others: Reserved.
1: One of Fixed Blanking or Floating Blanking and Warning
zone setting is enabled.
0: Fixed Blanking, Floating Blanking and Warning zone
setting are disabled.
1: PNP setting
0: NPN setting
1: Enable
0: Disable (setting is done by Tool)
1: Under the MUTING state
0: The other
1: Under the OVERRIDE state
0: The other
1: Muting setting is active and sequence error occurs.
2: The other
1: ON
0: OFF
1: When Fixed-Blanking or Floating Blanking beams are
unblocked
0: The other
1: ON
0: OFF
The incident light level data of each beam is output in 0 to
255 (8 bits) every beam (1 byte).
0 if SLC is not connected
The incident light level data of each beam is output in 0 to
255 (8 bits) every beam (1 byte).
0 if SLC is not connected
The incident light level data of each beam is output in 0 to
255 (8 bits) every beam (1 byte).
0 if SLC is not connected
Error code data is output in 8 bytes.
In order from upper to lower
1 byte: Error code
4 bytes: Power-ON Time (1 count every 15 minutes)
3 bytes: Data for inquiry*
Latest 6 records can be got.
* Please use the data for your inquiry.
E
F3SG-SR
155
User's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

F3sg-sr seriesF3sg-sra series

Table of Contents