 Detection capability
Detection capability for F3SG-SR differs based on the number of floating beams as shown below.
Model
F3SG-SR-14
F3SG-SR-25
F3SG-SR-45
F3SG-SR-85
 LED indicator status
When Floating Blanking is being enabled, the Blanking indicator turns on.
 Limitation for combination with other functions
You can use this function in combination with the Muting, Fixed Blanking, and Warning Zone functions
at the same time with the SD Manager 3. Settings for respective zone have limitations.
Refer to 2-1. Combination of Functions for more information on the use in conjunction with other functions.
Number of floating beams
configured
-
1 beam
2 beams
3 beams
4 beams
n beams
-
1 beam
2 beams
3 beams
4 beams
n beams
-
1 beam
2 beams
3 beams
4 beams
n beams
-
1 beam
2 beams
3 beams
4 beams
n beams
System Operation and Functions
Number of blocked beams to
Detection capability
turn safety outputs OFF
14 mm
24 mm
34 mm
44 mm
54 mm
14+(10×n) mm
25 mm
45 mm
65 mm
85 mm
105 mm
25+(20×n) mm
45 mm
85 mm
125 mm
165 mm
205 mm
45+(40×n) mm
85 mm
165 mm
245 mm
325 mm
405 mm
85+(80×n) mm
1 beam
2 beams
3 beams
4 beams
5 beams
(n+1) beams
1 beam
2 beams
3 beams
4 beams
5 beams
(n+1) beams
1 beam
2 beams
3 beams
4 beams
5 beams
(n+1) beams
1 beam
2 beams
3 beams
4 beams
5 beams
(n+1) beams
F3SG-SR