Omron F3SG-SRB Series User Manual page 115

Hide thumbs Also See for F3SG-SRB Series:
Table of Contents

Advertisement

 Factory default setting
Variable
Variable name
T1
Override input time limit
T2
Override time limit
 Basic wiring diagram
• External Device Monitoring used and in Manual Reset mode
PNP
24V/0V (Brown)
S3
S4
MUTE B/
COM(-) (Pink)
F3SG-SR
receiver
MUTE A/PRE-RESET/
PSDI/COM(+) (Gray)
RESET/EDM (Yellow) *1
0V/24V (Blue)
S1: Lockout or interlock reset switch or override switch
S2: Override cancel switch
S3, S4: Muting sensor
KM1, KM2: External device
*1. Also used as Override input line.
*2. Make sure to connect an override cancel switch to the RESET line when using the Override function.
Otherwise the OVERRIDE state may not be released by the override cancel switch, resulting in serious injury.
• External Device Monitoring not used and in Manual Reset mode
PNP
24V/0V (Brown)
S3
S4
MUTE B/
COM(-) (Pink)
F3SG-SR
receiver
MUTE A/PRE-RESET/
PSDI/COM(+) (Gray)
RESET/EDM (Yellow) *
0V/24V (Blue)
S1: Lockout/interlock reset switch or override switch or override cancel switch
S3, S4: Muting sensor
*1. Also used as Override input line.
Value
1 s
600 s
+24 VDC
S2
KM1
*2
KM2
S1
0V
+24 VDC
S1
0V
System Operation and Functions
Description
Maximum input time of override input.
The duration time of the Override function. The OVERRIDE state
is cancelled if it continues for longer than this time limit.
NPN
24V/0V (Brown)
S3
S4
MUTE B/
COM(-) (Pink)
F3SG-SR
receiver
MUTE A/PRE-RESET/
PSDI/COM(+) (Gray)
RESET/EDM (Yellow) *1
0V/24V (Blue)
NPN
24V/0V (Brown)
S3
S4
MUTE B/
COM(-) (Pink)
F3SG-SR
receiver
MUTE A/PRE-RESET/
PSDI/COM(+) (Gray)
RESET/EDM (Yellow) *
0V/24V (Blue)
0V
KM1
S2
KM2
S1
+24 VDC
0V
S1
+24 VDC
F3SG-SR
User's Manual
E
87

Advertisement

Table of Contents
loading

This manual is also suitable for:

F3sg-sr seriesF3sg-sra series