System Operation and Functions

2-19. Setting Zone Adjacency Conditions

If any two functions of Muting, Fixed Blanking or Warning Zone functions of the F3SG-SR are used at
the same time, the setting zones have limitations.
This section describes the limitations for following points:
1. Zone adjacent condition: If zones for multiple functions are configured adjacently
2. Zone overlap condition: If zones for multiple functions are configured as overlapped
2-19-1. Zone Adjacency Condition
The table below describes the conditions to configure setting zones for adjacent beams.
Except for some conditions, setting zones for these 3 functions can be located adjacently. The user
can make the setting by the SD Manager 3.
Zone adjacency condition
Muting
Fixed Blanking
Warning Zone
Yes: Possible to configure
* For details about setting adjacent fixed blanking zones.
Refer to Constraint between fixed blanking zones under 2-15. Fixed Blanking.
2-19-2. Zone Overlap Condition
The table below describes the conditions to configure setting zones for overlapping beams.
Except for combination of muting zone and fixed blanking zone (figure 1), setting zones of these 3
functions cannot be overlapped. (Figure 2)
The user can make the setting by the SD Manager 3.
Setting zones of Muting and Floating functions can be overlapped only if each zone covers the full detection zone.
Zone overlap condition
Muting
Fixed Blanking
Warning Zone
Yes: Possible to configure
No: Not possible to configure
F3SG-SR
108
User's Manual
Function
Function
Muting
Fixed Blanking
-
Yes
Yes
Muting
Fixed Blanking
-
Yes
No
Warning Zone
Yes
Yes
*
Yes
Yes
Warning Zone
Yes
No
No
No
No
-
-