To enable the MUTING state, D3 and d2 must satisfy formulas (3) and (4), respectively.
This distance must prevent the MUTING state from being enabled by a person passing through the
muting sensors. Also, install the F3SG-SR and muting sensors so that each workpiece passes through
all muting sensors before the next workpiece arrives at the first muting sensor.
Workpiece
Moving direction
 Wiring diagram (PNP)
Using a photoelectric sensor as a muting sensor
B1
A1
F3SG-SR
Note. Two-wire type muting sensor cannot be used.
Workpiece
Using an NO contact type switch as a muting sensor (PNP)
B2
A1, B1, A2, B2 :
Through-beam type
photoelectric sensor
- PNP Output
- Dark-ON
A2
System Operation and Functions
Workpiece
Workpiece
Moving direction
A1
A2
B1
B2
A1, A2, B1, B2:
NO contact type switch
+24 VDC
Power
supply
0 V
F3SG-SR
71