Control Unit
Appearance
Control Unit
Appearance
Control Unit
Appearance
Model
G9SX-AD322-T15
Safety output (solid-state):
source output (PNP) x 3
(instantaneous), source output
(PNP) x 2 (OFF-delayed)
Auxiliary output (solid-state):
source output (PNP) x 2
Model
G9SP-N10S
Safety output (solid-state):
source output (PNP) x 4
Test output (solid-state): source
output (PNP) x 4
Standard output (solid-state):
source output (PNP) x4
G9SP-N10D
Safety output (solid-state):
source output (PNP) x 16
Test output (solid-state): source
output (PNP) x 6
G9SP-N20S
Safety output (solid-state):
source output (PNP) x 8
Test output (solid-state): source
output (PNP) x 6
Model
NX-SIH400
Safety input (solid-state): sink
input (PNP) x 4
Test output (solid-state): source
output (PNP) x 2
NX-SID800
Safety input (solid-state): sink
input (PNP) x 8
Test output (solid-state): source
output (PNP) x 2
Output
• An F39-JGC Root-Straight
Cable or the combination of an
F39-JGR3K Root-Plug Cable for
Extended and an F39-JGA
Single-Ended Cable is required.
• An F3SG-SR in PNP system can
be connected.
• 16 patterns of OFF-delayed
output for up to 15 s can be set.
• The OFF-delayed output can be
used as instantaneous output by
setting it to 0 s.
• Can be configured for partial
control and total control.
• Can be extended to connect a
relay unit.
Output
• An F39-JGC Root-Straight
Cable or the combination of an
F39-JGR3K Root-Plug Cable for
Extended and an F39-JGA
Single-Ended Cable is required.
• An F3SG-SR in PNP system can
be connected.
Application
• An F39-JGC Root-Straight
Cable or the combination of an
F39-JGR3K Root-Plug Cable for
Extended and an F39-JGA
Single-Ended Cable is required.
• An F3SG-SR in PNP system can
be connected.
Appendix
Remarks
Remarks
Specifications
F3SG-SR
363