Omron F3SG-SRB Series User Manual page 251

Hide thumbs Also See for F3SG-SRB Series:
Table of Contents

Advertisement

 Readout Information
The user can view the following information related to a receiver or emitter.
If more than one sensor is cascaded in series, information on all the cascaded sensors is viewed
together.
Information
External wiring
Power Supply
OSSD 1 (Black)
OSSD 2 (White)
RESET (Yellow)
AUX (Red)
MUTE A (Gray)
MUTE B (Pink)
Sensor
Scan code
EDM
Interlock/Pre-Reset/PSDI
Fixed/Floating Blanking
PNP/NPN
DIP Enable/Disable
Operating Status
Muting information
Override information
Sequence error information
Safety output information
Push-SW information
Blanking beam unblocked
information
Setting with SD Manager 3
Description
The power supply voltage in the power-on status is displayed.
Linked with safety output 1
Linked with safety output 2
Linked with Reset/EDM/Override input
Linked with auxiliary output
Linked with MUTE A/Pre-Reset input/PSDI input
Linked with MUTE B input
Displays Scan Code configured
Displays EDM configuration
Displays Interlock/Pre-Reset/PSDI mode configured
Displays Fixed/Floating Blanking configured
Displays output mode (PNP/NPN) configured
Displays whether the settings by the DIP Switches are enabled or
disabled.
Linked with muting status
Linked with override status
Linked with muting sequence error status or interlock sequence
error status
Linked with safety output
Linked with the input signal of Push Switch
Linked with the state where the blanking beam is unblocked
E