System Operation and Functions
2-16-2. Factory Default Setting
The Floating Blanking is disabled.
2-16-3. Setting with Intelligent Tap
Floating blanking can be configured using Positions 6 and 7 of the DIP Switch of the Intelligent Tap.
The Floating Blanking Monitoring function is configured as Lockout.
Make sure the Position 2 of the DIP Switch is set at ON (DIP Switch Enabled) to activate the settings by the DIP Switch.
Refer to Chapter 3 Setting with Intelligent Tap for more information on setting this function by the Intelligent Tap.
2-16-4. Setting with SD Manager 3
The user can make changes to the settings of this function by the SD Manager 3.
Setting is required for each sensor segment in case of a cascade connection.
Function
Floating Blanking
Floating Blanking Monitoring
Temporarily Disable Monitoring
Function
Monitoring temporarily disabled
time limit
Number of floating beams
Number of allowable beams
It is recommended that the Position 2 of the DIP Switch be set at OFF (DIP Switch Disabled).
Setting the Floating Blanking Monitoring function to Disable Monitoring may create an undetectable area where a person
can block the F3SG-SR without being detected, and it is not compliant with IEC 61496-2. Conduct risk assessment
analysis thoroughly before enabling this setting.
Refer to Chapter 4 Setting with SD Manager 3 for more information on changing functions by SD Manager 3.
F3SG-SR
100
User's Manual
Initial value
Disable
Enable/Disable
Lockout
Disable monitoring/Lockout/Cancel blanking zone
Disable
Enable/Disable
10 s
1 to 200 s (1-s increments), or infinite
1
1 to 15 beams (1-beam increments)
0
0 to 5 beams (1-beam increments)
Configurable value or numerical range