Omron F3SG-SRB Series User Manual page 306

Hide thumbs Also See for F3SG-SRB Series:
Table of Contents

Advertisement

Wiring and Installation
2.
Fully loosen the Mounting Screws (hexagon socket head cap screw (M4×22)). Fit the Brackets (1) and
(2) to the backside of the sensor housing so that the groove of the backside of the housing receives the
hooks of the Brackets (1) and (2). (Fig. 2)
Loosen
Mounting Screw
(hexagon socket head
cap screw (M4×22))
3.
Securely tighten the Mounting Screws to fix the Adjustable Side-Mount Bracket to the sensor housing.
The recommended torque to tighten the Mounting Screws is 3.0 N•m. Then loosen the Alignment
Screws (hexagon socket head cap screws (M4×22)). (Fig. 3)
1. Securely 
tighten
2. Loosen
1. Securely 
tighten
2. Loosen
Mounting Screw
Alignment Screw
Tightening screws with a torque that considerably exceeds the recommended torque may cause failure.
F3SG-SR
278
User's Manual
Bracket (2)
Bracket (1)
Mounting Screw
Alignment Screw 
(hexagon socket head 
cap screw (M4×22))
Mounting Screw
Alignment Screw 
(hexagon socket head 
cap screw (M4×22))
Fig. 3
Fit the hooks of Adjustable
Side-Mount Brackets to the
groove of the backside of
the housing
Fig. 2
Hook

Advertisement

Table of Contents
loading

This manual is also suitable for:

F3sg-sr seriesF3sg-sra series

Table of Contents