Reduced Resolution - Omron F3SG-SRB Series User Manual

Hide thumbs Also See for F3SG-SRB Series:
Table of Contents

Advertisement

4-3-4-5. Reduced Resolution

First, carry out 4-3-1. Preparing to Change Settings.
Next, click the icon below on the Top page.
The setting screen below is displayed.
No.
Function name
1
Reduced resolution
2
No. of beams
For more information on reduced resolution, refer to 2-17. Reduced Resolution.
For more information on reduced resolution, refer to  Detection capability on 2-17. Reduced Resolution
It is not possible to configure the Reduced Resolution function together with the Muting function. To enable settings of
the Reduced Resolution function, disable the Muting function.
After changing the Muting function from Enable to Disable or from Disable to Enable, check the settings of these
functions again.
Affected functions: External Device Monitoring (EDM), Start Interlock, Restart Interlock, Auxiliary Output
When changing the settings is complete, confirm the settings and write the configuration to the F3SG-SR.
To enable the written configuration, refer to 4-2-7-3. Writing Configuration into Intelligent Tap.
When connecting the Intelligent Tap to a F3SG-SR and trying to return the F3SG-SR to [Detecting], follow step 4 of
4-1-3-2. Connection Procedure When Using USB Connector to restart the F3SG-SR and Intelligent Tap, or click the
[Monitor]
button.
Description
Select Enable or Disable for the Reduced Resolution
function.
Select desired number of beams to be ignored. Up to
three beams can be configured.
Setting with SD Manager 3
Configurable value or
Initial value
numerical range
Disable
Enable/Disable
1
1 to 3 beams
(in 1-beam increments)
F3SG-SR
User's Manual
E
213

Advertisement