Overview and Specifications
Model
Input voltage
Overvoltage category
(IEC 60664-1)
Indicators
Protective circuit
Insulation resistance
Dielectric strength
Functional
Mutual interference prevention
Cascade connection
Test function
Safety-related functions
F3SG-SR
14
User's Manual
F3SG-SRA-14
F3SG-SRB-14
TEST
Light emission stops when connected to 24 VDC
ON voltage: Vs-3 V to Vs (short circuit current: approx. 5.0 mA) *
OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 6.0 mA) *
Light emission stops when connected to 0 V
ON voltage: 0 to 3 V (short circuit current: approx. 6.0 mA)
OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 5.0 mA) *
OPERATING
Long: 12 V to Vs (short circuit current: approx. 4.2 mA) * or open
RANGE
Short: 0 to 3 V (short circuit current: approx. 4.2 mA)
SELECT
INPUT
RESET/EDM
PNP
ON voltage: Vs-3 V to Vs (short circuit current: approx. 9.5 mA) *
OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 13.0 mA) *
NPN
ON voltage: 0 to 3 V (short circuit current: approx. 13.0 mA)
OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 9.5 mA) *
MUTE A/B ,
PNP
PRE-RESET,
ON voltage: Vs-3 V to Vs (short circuit current: approx. 4.5 mA) *
PSDI
OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 7.0 mA) *
NPN
ON voltage: 0 to 3 V (short circuit current: approx. 7.0 mA)
OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 4.5 mA) *
*The Vs indicates a supply voltage value in your environment.
II
See  F3SG-SR Series for more information.
Output short-circuit protection
20 M or higher (500 VDC megger)
1,000 VAC, 50/60 Hz (1 min)
Optical synchronization by Scan Code: in up to 2 sets
Wired synchronization: in up to 3 sets
See 5-1-4. Mutual Interference Prevention for more information.
Number of cascaded segments: 3 max.
Total number of beams: 255 max.
Self-test (at power-on, and during operation)
External test (light emission stop function by test input)
Interlock
External Device Monitoring (EDM)
Pre-Reset
PSDI
Fixed Blanking/Floating Blanking
Reduced Resolution
Muting/Override
Mutual Interference Prevention
PNP/NPN Selection
Response Time Adjustment
See Chapter 2 System Operation and Functions and Chapter 3 Setting with
Intelligent Tap for more information.
F3SG-SRA-25
F3SG-SRA-45
F3SG-SRB-25
F3SG-SRB-45
F3SG-SRA-85
F3SG-SRB-85