Performing Backup - Omron F3SG-SRB Series User Manual

Hide thumbs Also See for F3SG-SRB Series:
Table of Contents

Advertisement

Setting with Intelligent Tap

3-6-2. Performing Backup

When performing the Backup, make sure to set the DIP Switch Position 1 at OFF (Unlock)
before turning on the power. If the DIP Switch Position 1 is at ON (Lock), the Restoration
is performed, which may case the settings of the F3SG-SR to be overwritten and a person
to go undetected, resulting in serious injury.
Follow the flowchart below to perform backup.
Intelligent Tap IN indicator
To run the Intelligent Tap while being connected to the F3SG-SR, you must save the F3SG-SR's
settings in the Intelligent Tap by the backup operation. After performing the Backup, set the DIP Switch
Position 1 at ON (Lock) and connect the Intelligent Tap to the F3SG-SR.
F3SG-SR
136
User's Manual
Backup
Power OFF
Connect Intelligent Tap to
F3SG-SR
Set all DIP Switches at OFF
Power ON
Intelligent Tap IN indicator
blinks slowly
Press and hold Push Switch
for over 1 sec
No
Yes
Perform Backup (copying
settings from F3SG-SR
to Intelligent Tap)
Yes
Backup successful?
Intelligent Tap IN indicator
blinks fast and ERR
blinks fast
indicator lights up
Turn OFF power and
disconnect Intelligent Tap
from sensor
Set DIP Switch Position 1
at ON (Lock)
End
All F3SG-SR indicators other than ABI or
TOP/BTM indicator blink sequentially.
When using SD Manager 3 by connect-
ing Intelligent Tap to PC, connecting
online is not possible during slow blinking
of IN indicator. Press Push Switch to
perform Backup and then connect online
via SD Manager 3.
No
If not, settings backed up here may be
accidentally overwritten later.

Advertisement