Arm/leg protection (Detection capability: 45-mm dia.)
Number
Model
of beams
F3SG-4SR0240-45
F3SG-4SR0400-45
F3SG-4SR0560-45
F3SG-4SR0720-45
F3SG-4SR0880-45
F3SG-4SR1200-45
F3SG-4SR1520-45
Note 1. The maximum speed of movement of a test rod up to which the detection capability is maintained is 2.0 m/s.
Note 2. The response times are values when Scan Code is set at Code B. The response times for Code A are 1 ms shorter than
these values.
Refer to 2-3. Mutual Interference Prevention for more information.
Body protection (Detection capability: 85-mm dia.)
Number
Model
of beams
F3SG-4SR0280-85
F3SG-4SR0440-85
F3SG-4SR0600-85
F3SG-4SR0760-85
F3SG-4SR0920-85
Note 1. The maximum speed of movement of a test rod up to which the detection capability is maintained is 2.0 m/s.
Note 2. The response times are values when Scan Code is set at Code B. The response times for Code A are 1 ms shorter than
these values.
Refer to 2-3. Mutual Interference Prevention for more information.
Response time
(Optical synchronization)
Protective
height
[mm]
ON to
(synchronized)
OFF
to ON
6
240
8
10
400
8
14
560
8
18
720
8
22
880
8
30
1200
8
38
1520
8
Response time
(Optical synchronization)
Protective
height
[mm]
ON to
(synchronized)
OFF
to ON
4
280
8
6
440
8
8
600
8
10
760
8
12
920
8
Overview and Specifications
Response time
(Wired
synchronization)
[ms]
[ms]
OFF
OFF (not
ON to
synchronized)
OFF
to ON
40
140
10
40
140
10
40
140
10
40
140
10
40
140
10
40
140
10
40
140
10
Response time
(Wired
synchronization)
[ms]
[ms]
OFF
OFF (not
ON to
synchronized)
OFF
to ON
40
140
10
40
140
10
40
140
10
40
140
10
40
140
10
OFF to
ON
50
50
50
50
50
50
50
OFF to
ON
50
50
50
50
50
F3SG-SR
User's Manual
E
23