Detailed Parameter Listings; Group 0: P0-Xx Monitor Parameters - Delta ASDA-A2 Series User Manual

High resolution ac servo drive for network communication applications
Hide thumbs Also See for ASDA-A2 Series:
Table of Contents

Advertisement

Chapter 8 Servo Parameters|ASDA-A2 Series
8.3

Detailed Parameter Listings

Group 0: P0-xx Monitor Parameters

P0 - 00★
VER
Firmware Version
Default: Factory setting
Applicable Control Mode: ALL
Unit: N/A
Range: N/A
Data Size: 16-bit
Display Format: Decimal
P0 - 01■
ALE
Drive Fault Code
Default: N/A
Applicable Control Mode: ALL
Unit: N/A
Range: 001 ~ 380
Data Size: 16-bit
Display Format: BCD
Settings:
This parameter shows the current servo drive fault if the servo drive is currently faulted.
The fault code is hexadecimal data but displayed in BCD format (Binary coded decimal).
Servo Drive Fault Codes:
001: Overcurrent
002: Overvoltage
003: Undervoltage (This fault code shows when main circuit voltage is below its minimum
specified value while Servo On, and it will not show while Servo Off. This fault code can't be
cleared automatically after the voltage has returned within its specification. Please refer to
parameter P2-66.)
004: Motor error (The drive and motor are not correctly matched for size (power rating).
005: Regeneration error
006: Overload
007: Overspeed
008: Abnormal pulse control command
009: Excessive deviation
010: Reserved
011: Encoder error (The wiring of the encoder is in error and this causes the communication
error between the servo drive and the encoder.)
012: Adjustment error
8-30
Address: 0000H, 0001H
Related Section: N/A
Address: 0002H, 0003H
Related Section: Chapter 11
Revision April, 2010

Hide quick links:

Advertisement

Table of Contents
loading