This chapter describes the basic operation of the digital keypad and the features it offers.
4.1

Description of the Digital Keypad

The digital keypad includes the display panel and function keys. The Figure 4.1 shows all of the features of
the digital keypad and an overview of their functions.
Figure 4.1 Keypad Features
Name
LCD Display
Charge LED
MODE Key
SHIFT Key
UP and DOWN Key
SET Key
Revision April, 2010

Chapter 4 Display and Operation

The LCD Display (5-digit, 7-step display panel) shows the monitor codes,
parameter settings and operation values of the AC servo drive.
The Charge LED lights to indicate the power is applied to the circuit.
MODE Key. Pressing MODE key can enter or exit different parameter groups, and
switch between Monitor mode and Parameter mode.
SHIFT Key. Pressing SHIFT key can scrolls through parameter groups. After a
parameter is selected and its value displayed, pressing SHIFT key can move the
cursor to the left and then change parameter settings (blinking digits) by using
arrow keys.
UP and DOWN Key. Pressing the UP and DOWN key can scroll through and
change monitor codes, parameter groups and various parameter settings.
SET Key. Pressing the SET key can display and save the parameter groups, the
various parameter settings. In monitor mode, pressing SET key can switch decimal
or hexadecimal display. In parameter mode, pressing SET key can enter into
parameter setting mode. During diagnosis operation, pressing SET key can
execute the function in the last step. (The parameter settings changes are not
effective until the SET key is pressed.)