Performing the upgrade

Upgrading Core 0

Adding Side 0 FIJI hardware
NN43021-466
Standard 06.02
Procedure 15
Checking that Core 1 is active
To upgrade Core 0, verify that Core 1 is the active side performing
call processing:
1
Verify that Core 1 is active:
LD 135
STAT CPU
Procedure 16
Checking that Clock Controller 1 is active
1
Check the status of the Clock Controllers:
LD 60
SSCK 1
Procedure 17
Install Side 0 FIJI cards
1
Unpack the FIJI cards (NTRB33).
2
Faceplate-disable the NTRB33 cards.
1
Insert and seat the FIJI cards in all Side 0 shelves.
Note: Double slot FIJI cards install in slots 2 and 3 of the Network
modules, and slots 8 and 9 of the Core/Net modules. Single slot FIJI cards
(with vintages equal to or later than NTRB33BBE5) install in slot 2 of the
Network modules, and slot 9 of the Core/Net modules.
December 2013
Load program
Obtain the status of the CPUs
End of Procedure
Load program
Obtain the status of Clock Controller 1
End of Procedure
End of Procedure