Avaya Meridian 1 Series Upgrade Manual page 40

Communication server cs 1000m sg cp piv to cs 1000m mg cp piv fnf upgrade
Table of Contents

Advertisement

Connecting the shelf 1 FIJI Ring cables (descending)
Create Fiber Ring 1. Connect the FIJI cards in all Network shelves 1 in
descending order, from Tx to Rx (
Remove the black cap from the end of each cable before it is connected.
Note: Each end of the NTRC48xx cable is labeled "Tx" or Rx" in the
factory.
1
Start with Network group 0, shelf 1.
2
Connect a NTRC48xx FIJI Fiber Ring cable of the appropriate length from
the Tx (J1) port of the FIJI card in Group 0, shelf 1 to the Rx (J2) port of
the FIJI card in the highest Network group, shelf 1.
3
Connect a NTRC48xx cable from the Tx (J1) port of the FIJI card from the
Tx (J1) port in the highest Network group, shelf 1 to the Rx (J2) port in
the second highest Network group, shelf 1.
4
Continue to connect NTRC48xx FIJI Fiber Ring cables of the appropriate
length from the Tx (J1) port to the Rx (J2) port in shelf 1 of each Network
group. Connect these cables in descending order of Network groups.
Performing the upgrade
The shortest Fiber Cable must always be used.
The cables from group 0 to group 1 must always be the
same length as the cables from the last group back to
group 0
The distance between the lengths of each fiber ring from
group 0 to any other group must not exceed 50'. Rings
are directional. Ring 0 is ascending and ring 1 is
descending.
Note: When adding an additional network group, fiber
cables must be changed to adhere to the rules above.
CS 1000M SG CP PIV to CS 1000M MG CP PIV FNF Upgrade
IMPORTANT!
Figure 5 on
page 41
Page 40 of 159
.)

Advertisement

Table of Contents
loading

This manual is also suitable for:

1000m seriesCs 1000m sgCs 1000m mg

Table of Contents