Performing the upgrade
Procedure 27
Testing Core/Net 0
From active Core/Net 0, perform these tests on Core/Net 1:
1
Perform a redundancy sanity test:
LD 135
STAT CPU
TEST CPU
2
Test the System Utility card and the cCNI cards:
LD 135
STAT SUTL
TEST SUTL
STAT CNI c s
TEST CNI c s
3
Test system redundancy and media devices:
LD 137
TEST RDUN
DATA RDUN
STAT FMD
STAT RMD
****
4
Test that the system monitors are working:
LD 37
STAT XSM
****
December 2013
Load program
Obtain status of CPU and memory
Test the CPU
Load program
Obtain the status of the System Utility card
Test the System Utility card
Obtain status of cCNI cards (core, slot)
Test cCNI (core, slot)
Load program
Test redundancy
Test database integrity
Status of Fixed Media Device (FMD)
Status of Removable Media Device (RMD)
Exit the program
Load program
Check the system monitors
Exit the program