Avaya Meridian 1 Series Upgrade Manual page 76

Communication server cs 1000m sg cp piv to cs 1000m mg cp piv fnf upgrade
Table of Contents

Advertisement

a.
Connect P1 of the NTRC46 cable from Clock 1 to J3 of the FIJI card
in group 0, shelf 0.
Procedure 21
Enabling Clock Controller 0 and Ring 0
1
Hardware enable FIJI cards in RIng 0 and hardware enable Clock
Controller 0.
a.
Check that the Fiber Rings operate correctly:
LD 39
ENL RING 0
STAT RING 0
STAT RING 1
b.
Restore the Rings to Normal State:
RSET
RSTR
ARCV ON
CS 1000M SG CP PIV to CS 1000M MG CP PIV FNF Upgrade
Performing the upgrade
End of Procedure
Load program
Enable Ring 0
Check the status of Ring 0 (HALF/HALF)
Check the status of Ring 1 (HALF/HALF)
Reset threshold for Ring switchover
Restore both Rings to HALF state
Turn Auto Recovery on
Page 76 of 159