Avaya Meridian 1 Series Upgrade Manual page 104

Communication server cs 1000m sg cp piv to cs 1000m mg cp piv fnf upgrade
Table of Contents

Advertisement

5
Clear the display and minor alarms on both Cores:
LD 135
CDSP
CMAJ
CMIN ALL
6
Test the clocks:
a.
Verify that the clock controller is assigned to the active Core.
LD 60
SSCK x
SWCK
****
b.
Verify that the Clock Controllers are switching correctly.
SWCK
SWCK
7
Check dial tone.
8
Check applications.
CS 1000M SG CP PIV to CS 1000M MG CP PIV FNF Upgrade
Performing the upgrade
Load program
Clear the displays on the cores
Clear major alarms
Clear minor alarms
Load program
Obtain the status of the clock controllers
(x is "0" or "1" for Clock 0 or Clock 1)
Switch the Clock (if necessary)
Exit program
Switch the Clock
Note: You must wait a minimum of one minute for
clocks to synchronize.
Switch the Clock again
End of Procedure