Page 77 of 159
Performing the upgrade
CS 1000 Release 7.5 upgrade
NN43021-466
Standard 06.02
c.
Check that the Rings operate correctly:
STAT RING 0
STAT RING 1
****
d.
Check the status of Clock Controller 0
LD 60
SSCK x
****
Upgrading the software
Procedure 22 outlines the steps involved in installing CS 1000 Release 7.5
for the CP PIV processor.
Procedure 22
Upgrading the software
1
Check that a terminal is now connected to COM 1port in CP 1. The
settings for the terminal are:
a.
Terminal type: VT100
b.
9600 Baud
c.
Data bits: 8
d.
Parity: none
e.
Stop bits: 1
f.
Flow control: none
2
Insert the RMD into the CF card slot on Call Processor 1 (inactive).
December 2013
Check status of Ring 0 (HALF/HALF)
Check status of Ring 1 (HALF/HALF)
Exit program
Load program
Obtain status of the clock controllers (x is "0" or
"1" for Clock 0 or Clock 1)
Exit program
End of Procedure