Figure 10
Shelf 0 ascending fiber optic Ring (Meridian 1 Option 81C 5 group example)
Group 4, shelf 1
Tx (J1)
Rx (J2)
Group 4, shelf 0
Tx (J1)
Rx (J2)
Group 3, shelf 1
Tx (J1)
Rx (J2)
Group 3, shelf 0
Tx (J1)
Rx (J2)
NTRC48xx fiber optic cable
IPE
Group 2, shelf 1
Tx (J1)
Rx (J2)
Group 2, shelf 0
Tx (J1)
Rx (J2)
Group 0, shelf 1
Tx (J1)
Rx (J2)
Procedure 20
Cabling the Clock Controllers to FIJI card
Connect the cables to the Clock Controllers as shown in
1
Connect the Clock 0 to FIJI cable:
a.
Connect P1 of the NTRC46 cable from Clock 0 to J4 of the FIJI card
in group 0, shelf 0.
b.
Connect P2 of the NTRC46 cable for Clock 0 to J4 of the FIJI card in
group 0, shelf 1
2
Connect the Clock 1 to FIJI cable:
CS 1000M SG CP PIV to CS 1000M MG CP PIV FNF Upgrade
Performing the upgrade
IGM
(not used with
Fiber Network)
Group 1, shelf 1
Tx (J1)
Rx (J2)
Group 1, shelf 0
Tx (J1)
Rx (J2)
Group 0, shelf 0
Tx (J1)
Rx (J2)
Page 74 of 159
IPE
IPE
IPE
IPE
553-9553
Figure 11 on
page 75
: