Performing the upgrade
Reconfiguring I/O ports and call registers
NN43021-466
Standard 06.02
Procedure 11
Reconfiguring I/O ports and call registers
1
Evaluate the number of call registers and 500 telephone buffers that are
configured for the system (suggested minimum values are 20,000 and
1000 respectively). If changes are required, reconfigure the values in LD
17:
LD 17
CHG
CFN
PARM YES
500B 1000
NCR 20000
****
2
Print the Configuration Record to confirm the changes made above:
LD 22
REQ PRT
TYPE CFN
****
At this point, all applications must be shut down.
December 2013
Load program
Use 1000 as a minimum value
Use 20000 as a minimum value
Exit program
Load program
Set the print Option
Print the configuration
Exit program