Siemens HiPath 3000 Series Service Documentation page 76

Table of Contents

Advertisement

sysdat.fm
System Data
HiPath 3000
Trunk Boards
Table 2-19
Trunk Boards for HiPath 3500
Board
Capacity
Name
1
TCASR-2
2 60
STLS4R
4
8
TLA4R
4
TLANI4R
4
TMGL4R
4
TS2R
30 30
TST1
1
24
1
TCASR-2 provides two E1 CAS interfaces which, combined, can support up to 60 B channels.
As HiPath 3500 supports a maximum of 30 B channels, a total of up to 30 B channels may be used.
2
For selected countries only
3
The maximum number is calculated on the basis of the system-specific capacity limits, See Section 2.3, "System-Specific
Capacity Limits for HiPath 3000, HiPath 5000".
2-36
Coun-
try
2
1
x
- Board for supporting country-specific
CAS (Channel Associated Signaling) protocols
3
#
x
x Board for ISDN basic access. Permits configuration of ISDN
trunks, tie trunks, and subscribers (no feeding) on the same
board.
3
#
x
- Trunk board for analog lines including ALUM and call me-
tering receiving equipment board
3
#
x
x Trunk board for analog lines including ALUM
3
#
-
x Trunk board for analog lines
1
x
- In HiPath 3000/5000 V5.0 and later, the B channels in the
TS2R board are subject to license. Consequently, the TS2R
board S30810-K2913-Z300 has been assigned a new hard-
ware identification code. The new code prevents the board
from being used in earlier versions. Functionality and layout
of the board have not been changed.
1
-
x PRI board
Nur für den internen Gebrauch
Type/Description
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation

Hide quick links:

Advertisement

Table of Contents
loading