Inserting Or Removing Boards - Siemens HiPath 3000 Series Service Documentation

Table of Contents

Advertisement

inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
4.1.5.3

Inserting or Removing Boards

Caution
7
Always wear an antistatic wristband when working on the system (especially when
handling boards).
Observe the measures for protecting electrostatically sensitive devices (see
Section 1.2.6, "Notes").
Introduction
Peripheral boards can be inserted and removed while the power is connected. Always use the
board wrench provided for removing and inserting boards.
See Section 9.1.1 for information on upgrading peripheral boards.
Procedure for inserting and removing the boards
If
Board is to
Insert the tip of the board wrench marked "Pull" into the top opening on the front
be re-
cover of the board to be removed.
moved.
Lever the board out of the shelf by pushing the board wrench upwards (Figure 4-
16, left).
Then you can pull the module out of the system cabinet over the guide rails.
Board is to
Using its guide rails slide the board into the system cabinet until it stops.
be added.
Insert the tip of the board wrench marked "Plug-In" into the bottom opening in the
front cover of the board.
Lever the board into the shelf of the cabinet by pushing the board wrench up-
wards (Figure 4-16, right).
Removing a board
Figure 4-16
HiPath 3800 - Removing/Inserting the Board Using the Board Wrench
4-34
Nur für den internen Gebrauch
Then
Inserting a board
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation