Tla4R (Not For U.s.) - Siemens HiPath 3000 Series Service Documentation

Table of Contents

Advertisement

boards.fm
Boards for HiPath 3000
Peripheral boards
3.3.30

TLA4R (not for U.S.)

NOTE
>
Danger of damage to property due to surge voltage. The required lightning protec-
tion measures must be taken for this board, see Section 2.1.2, "Lightning Protec-
tion".
Introduction
The TLA4R (Trunk Line Analog Rack) board provides four ports for the analog trunk connection
(DP and DTMF signaling methods) on HiPath 3500 and HiPath 3300 (19-inch housing). There
are also two ALUM power failure transfers.
The transmission and function-oriented characteristics of the TLA4R are completely identical
to those of the
TLA boards
are
the two ALUMs which are only available on the TLA4R.
the call metering receiving equipment interface, which is only on the TLA boards.
Interfaces
Trunk 1
:
:
Trunk 4
8 MW8
jacks
ALUM
1 + 2
Figure 3-91
TLA4R (not for U.S.) - Interfaces (S30817-Q923-Zxxx)
3-260
that are used in HiPath 3550 and HiPath 3350. The only differences
11
18
21
:
X5
88
Nur für den internen Gebrauch
50
X1
2
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
to CUPR/
CUCR