Siemens HiPath 3000 Series Service Documentation page 414

Table of Contents

Advertisement

boards.fm
Boards for HiPath 3000
Peripheral boards
Jumper for setting the procedure for analog trunk interfaces
The procedure for the analog trunk interfaces is set via jumper X100 and X101.
Loop start setting = pins 1–2 closed (default)
Ground start setting = Pins 2 – 3 closed [not with IM and BRA]
LED statuses and their meanings
Table 3-134
TMANI8 - LED States
Red LED
Green
LED
Off
Off
On
Off
Flashing
Off
Off
On
Off
Flashing At least one subscriber line circuit is activat-
Cable and connector assignment
For connecting to the SIVAPAC connector on the backplane: Table 3-135
For connecting to the connector panels using RJ45 jacks: Table 3-136
For U.S. only: For connecting to the connector panels with CHAMP jack: Table 3-137
For connecting to the connector panels using SIPAC 1 SU connectors: Table 3-138
3-282
Status
Board not receiving power or not plugged in
correctly.
Board is out of order.
Board is receiving power and board test is in
progress.
Board is defective if status remains un-
changed (board test unsuccessful).
Loadware loading not successfully complet-
ed. Board is faulty.
Error detected on board.
Board is deactivated (not applicable to er-
rors detected by test loops) or board was de-
activated using HiPath 3000/5000 Manager
E.
Loadware is being loaded.
Board test completed successfully. Board is
OK (idle state).
ed.
Nur für den internen Gebrauch
Check plug contact on
board.
Replace board.
Replace board.
Check whether the board
was deactivated using Hi-
Path 3000/5000 Manager
E. If not, replace board.
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
Action