LED statuses and their meanings
Table 3-86
SLMAV8, SLMAV24 – LED statuses
Red LED
Green
LED
Off
Off
On
Flashing Board performs a self-test.
Slow
Off
flashing
Fast
Off
flashing
Off
On
Off
Flashing At least one subscriber line circuit is activat-
On
On
Cable and connector assignment
For connecting to the SIVAPAC connector on the backplane: Table 3-87
For connecting to the connector panels using RJ45 jacks: Table 3-88
For U.S. only: For connecting to the connector panels with CHAMP jack: Table 3-89
For connecting to the connector panels using SIPAC 1 SU connectors: Table 3-90 and
Table 3-91
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
Status
Board not receiving power or not plugged in
correctly.
Board is out of order.
Board is faulty.
Loadware is being loaded.
Loading was successfully completed and
board is OK (idle state). No subscriber line
circuit is active.
ed.
Unrecoverable hardware or loadware error Replace board.
boards.fm
Boards for HiPath 3000
Peripheral boards
Action
Check plug contact on
board.
Replace board.