boards.fm
Boards for HiPath 3000
Peripheral boards
An additional shielding panel is not required on the front side of this board, because the EMC
shield is already provided by the front panel.
V.24 interface
The
V.24 cable
(C30267-Z355-A25) is used for connecting the service PC.
The following settings must be chosen for a terminal or PC connected to the V.24 interface:
Transmission rate
Data bits
Parity bit
Stop bits
Data flow control
It is recommended that the local echo be deactivated on the connected terminal or PC.
Table 3-113
STMI2 - V.24 Interface Assignment
Pin
Signal
1
DCD
2
RXD
3
TXD
4
DTR
5
0 V
6
DSR
7
RTS
8
CTS
9
RI
3-242
38,400 (default)
8
None
1
None
I/O
Not used
I
Internal pull-up resistor in level switch (MAX211E)
O
O
Ground
I
Internal pull-up resistor in level switch (MAX211E)
O
I
Internal pull-up resistor in level switch (MAX211E)
Not used
Nur für den internen Gebrauch
Remark
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation