sysdat.fm
System Data
HiPath 3000
Trunk Boards
Table 2-11
Trunk Boards for HiPath 3550
Board
Capacity
Name
1
TCAS-2
2 60
TLA
2
TLA4
4
TLANI2
2
TLANI4
4
TLANI8
8
TLA8
8
TS2N
30 30
STLS2
2
4
STLS4
4
8
TST1
1
24
TMGL4
4
TMQ4
4
8
1
TCAS-2 provides two E1 CAS interfaces which, combined, can support up to 60 B channels. As HiPath 3550 supports a
maximum of 30 B channels, a total of up to 30 B channels may be used.
2
For selected countries only
2-28
Coun-
try
2
1
x
- Board for supporting country-specific
CAS (Channel Associated Signaling) protocols
3
#
x
- Trunk board for analog lines
3
#
x
- Trunk board for analog lines
3
#
x
x Trunk board for analog lines including ALUM
3
#
x
x Trunk board for analog lines including ALUM
3
#
x
x Trunk board for analog lines including ALUM
3
#
x
- Trunk board for analog lines
1
x
- Board for primary rate access; can be used for tie trunk traf-
fic.
In HiPath 3000/5000 V5.0 and later, the B channels in the
TS2N board are subject to license. Consequently, the
TS2N boards (S30810-Q2913-X300) have been assigned
a new hardware identification code. The new code prevents
the board from being used in earlier versions. Functionality
and layout of the board have not been changed.
3
#
x
- Board for ISDN basic rate access.
Configuration of ISDN trunks, tie trunks, and stations (no
3
#
x
x
feeding) on the same board is possible.
1
-
x PRI board
3
#
-
x Trunk board for analog lines
3
#
-
x BRI board
Nur für den internen Gebrauch
Type/Description
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents