ANI4R (for selected countries only)

NOTE
>
Danger of damage to property due to surge voltage. The required lightning protec-
tion measures must be taken for this board, see Section 2.1.2, "Lightning Protec-
tion".
Introduction
The ANI4R (Automatic Number Identification Rack) board is responsible for receiving station
numbers modulated using the CPFSK method, demodulating them, and forwarding them to the
HiPath 3500 or HiPath 3300 base system. In V4.0 SMR-7 or later, the station name is analyzed
in addition to the call number and shown on the telephone display.
Each ANI4R module can serve four trunks. It contains the external trunk board hardware inter-
faces (TMGL4R) and the options bus interface.
If ANI4R is installed as option 1 or 2,
>
8 (slots 6 and 8 not available with HiPath 3300).
Interfaces
TMGL4R
Figure 3-131
ANI4R (for selected countries only) (S30807-Q6917-Z103)
3-364
1
X3 (10-pin MW10 jack)
10
TMGL4R
board must be inserted in slot 4, 6 or
To OPALR, or previous option
ANI4R
Board side
A31003-H3590-S100-7-7620, 06/2012