Siemens HiPath 3000 Series Service Documentation page 202

Table of Contents

Advertisement

boards.fm
Boards for HiPath 3000
Central Board
The batteries were fully charged when the measurement was started.
The maximum bridging times given in the tables are basic orientation values. They can vary
from the values given here depending on your system configuration.
Table 3-26
HiPath 3350 – Maximum bridging times
Power supply unit
UPSC-D
48-V/1.2-Ah battery pack
UPSC-D
Powerbox PB3000 with 48 V/7 Ah
(4 x 12 V/7 Ah) battery pack
Table 3-27
HiPath 3550 – Maximum bridging times
Power supply unit
UPSC-D
48-V/1.2-Ah battery pack
UPSC-D
48-V/1.2-Ah battery pack
UPSC-D
Powerbox PB3000 with 48 V/7 Ah
(4 x 12 V/7 Ah) battery pack
3-70
Load levels
Normal output load 100 % =
5 V und 3 A / –48 V und 0,5 A;
ringing approx. 2 VA
Normal output load 100 % =
5 V und 3 A / –48 V und 0,5 A;
ringing approx. 2 VA
Load levels
Normal output load 100 % =
5 V and 8 A / –48 V and 1.1 A;
ringing approx. 4 VA
Normal output load 60 % =
5 V und 4,8 A / –48 V und 0,66 A;
ringing approx. 2 VA
Normal output load 60 % =
5 V und 4,8 A / –48 V und 0,66 A;
ringing approx. 2 VA
HiPath 3000/5000 V9, Service documentation
Nur für den internen Gebrauch
Maximum bridging
time
19 min
Maximum bridging
time
6 min
15 min
2 h 30 min
A31003-H3590-S100-7-7620, 06/2012
3 h