Boards for HiPath 3000
Peripheral boards
Administration of the CAS protocol converter
A separate tool, the CAS Manager, is used to download the software and administer the TCAS-
2 and TCASR-2. The CAS Manager software is stored on a CD supplied with the card. For in-
formation on how to install the CAS Manager software on the Service PC, refer to the readme
file.
The following options are available for accessing the cards:
Via the V.24 interface (9-pin MINI DIN jack X803) and the connection cable C39195-
A9700-B532.
Via the Ethernet (10/100BaseT) interface (RJ45 jack X804).
Via the optional analog modem (modem kit F31505-E1-A147). In this case, you will need
to establish a connection from the analog modem (RJ45 jack X805) to a free port in an an-
alog subscriber line module via the RJ45 cable C39195-Z7208-A10 supplied with the mo-
dem kit (see Figure 3-85).
HiPath 3550 / HiPath 3500
Analog sub-
scriber line
module
Establish connec-
Analog trunk
board
PSTN
Figure 3-84
TCAS-2, TCASR-2 (for selected countries only) – Connection Options for Card
Administration using CAS Manager
3-252
TCAS-2 /
TCASR-2
X805
Modem
(optional)
tion.
CAS
Manager
Nur für den internen Gebrauch
X803
V.24 interface
X804
Ethernet (10/100BaseT) interface
CAS
Manager
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
CAS
Manager
IP Network