Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
Static Traffic Capacity
The HiPath 3550 and HiPath 3350 systems have the following static traffic capacities.
Table 4-12
HiPath 3550 and HiPath 3350 - Static Traffic Capacity
System
HiPath 3550
(see Figure 4-58)
HiPath 3350
(see Figure 4-61)
1
Use of a TS2N board results in a capacity of 30 erlangs. A maximum of one TS2N per HiPath 3550 is possible, and the
board may only be installed in slot 7 or 9, thus resulting in 30 Erlangs for slot 7 or 9.
4-108
Slots
Static traffic capac-
2 / 3 (CBCC)
4
5
6
7
8
9
10
2 / 3 (CBCC)
4
5
Total static traffic capacity
ity
24 erlangs
16 erlangs
16 erlangs
16 erlangs
16 erlangs
16 erlangs
1
30 erlangs
64 erlangs
24 erlangs
16 erlangs
16 erlangs
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
Nur für den internen Gebrauch
of the system
198 erlangs