Peripheral boards
V.24 interface
The
V.24 cable
(C30267-Z355-A25) is used for connecting the service PC.
The following settings must be chosen for a terminal or PC connected to the V.24 interface:
Transmission rate
Data bits
Parity bit
Stop bits
Data flow control
It is recommended that the local echo be deactivated on the connected terminal or PC.
Table 3-41
HXGS3/HXGR3 - Assignment of V.24 Interface X10
Pin
Signal
1
2
RXD
3
TXD
4
DTR
5
0 V
6
DSR
7
RTS
8
CTS
9
3-100
19,200
8
None
1
None
I/O
I
Internal pull-up resistor in level switch (MAX211E)
O
O
Ground
I
Internal pull-up resistor in level switch (MAX211E)
O
I
Internal pull-up resistor in level switch (MAX211E)