Additional System Load - Siemens HiPath 3000 Series Service Documentation

Table of Contents

Advertisement

exup.fm
Expanding and Upgrading HiPath 3000
Upgrading HiPath 3000
9.2.3.2

Additional System Load

Overview
Activation of the Signaling & Payload Encryption feature has the following consequences for
the HiPath network:
Higher bandwidth requirement due to continuous TLS sessions for:
Connections to HFA terminals (CorNet-IP TC/TS, H.225 CS)
Connections for SIP terminals (SIP including SDP)
H.323 and SIP trunking connections
Higher bandwidth requirement:
Due to the fill and authentication algorithms used by TLS during transmission of user
data
Due to the proprietary encryption protocols used for IPDA and CTI connections
Due to SRTP/SRTCP
Higher network traffic due to periodic downloads of CRL ( Certificate Revocation List) or
delta CRL by each Gateway
Higher network traffic due to recently introduced protocols
H.235 Annex D for DMC Slave connections
MIKEY messages
Additional data due to protocol extensions:
CorNet-TC/TS plus X messages
H.225 RAS (LEGK communication)
CorNet NQ
Because of the many configuration options and scenarios possible, it is difficult to accurately
determine the effects of this feature on the system, that is, the additional bandwidth require-
ment and the increased data traffic volume. The following sections are intended as suggestions
on how to calculate the additional system load.
9-36
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation

Hide quick links:

Advertisement

Table of Contents
loading