Siemens HiPath 3000 Series Service Documentation page 278

Table of Contents

Advertisement

boards.fm
Boards for HiPath 3000
Peripheral boards
Options for supplying power to the base stations
For information on connecting the base stations, refer to the HiPath Cordless Office
>
service manual.
Each base station must be connected to the SLC16N via the main distribution frame (MDFU or
MDFU-E).
Always route the U
P0/E
to lightning. To do so, insert the polarized surge protectors (supplied) in the plugging locations
on the splitting strip from above.
The following options are available for supplying power to the base stations:
Power supply via one U
Power supply via two U
Power supply via three U
If the power supplied by the UPSC-D (HiPath 3550) is insufficient, additional power can be sup-
plied by installing the external power supply (Powerbox PB3000 with LUNA2 (Page 3-149).
Signal propagation times differ due to the varying distances between the base stations, the sys-
tem, and the connection cables used (refer to the HiPath Cordless Office service manual). The
SLC16N board automatically balances these propagation times.
3-146
interfaces on the SLC16N via a splitting strip to arrest surges caused
interface (Page 3-147)
P0/E
interfaces (Page 3-148)
P0/E
interfaces (Page 3-149), for BS3/3 only
P0/E
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation