4 Repair
4.4.2 Refitting the cable harness
Continued
Required consumables
Consumable
Cable ties
Loctite 574
Sikaflex
Refitting the cable harness
Use these procedures to refit the cable harness.
Refitting the cable harness in the base
1
2
3
Continues on next page
216
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
Refit the connection plate in the base (if it
has been removed).
Use caution and run the cable harness
through the hole in the frame and out to
the base plate.
© Copyright 2015-2018 ABB. All rights reserved.
Article number
Note
-
Flange sealant
Note
Attachment screws: M6x16 stainless steel
A2-70 (4 pcs)
Tightening torque: 6 Nm
xx1500003088
Product manual - IRB 8700