Step by Step
1

External Line DISA

Configures an external line for DISA answering mode.
The system allows only one DISA call. When there is a
DISA call in progress, a second call to a DISA external
line or with DISA answering mode is treated as a regular
call. If a call is received over an external line configured
as a Fax/DID and DISA, the call is answered by the Fax/
DID if this facility is available at the moment.
Required: Programming Mode must be active (*95
31994).
Enter the code for programming.
0
2 0
Enter the code for an external analog line (e.g., 801).
...
Select an answering timeout for DISA:
4
= Never (default)
1
= Night only
2
= Day only
3
= Always
4
Enter the next number for an external analog line.
or
Press this key.
#
Initial state for Programming Mode.
The MSN number must be registered in the Ex-
ternal Number Registration (Code 191).
When an digital line is used for the DISA feature,
its MSN number ("MSN DISA" - Code 019) is al-
ways active for answering DISA.
When DISA is activated for incoming external
calls on an external analog line, all calls are an-
swered by DISA.