12. Data Memory

Data memory is a function to store weighing data and calibration data in memory. The data stored in
memory are available for outputting at one time to a printer or personal computer.
Weighing data
Calibration report: Using the internal mass and an external weight
Calibration test report: Using the internal mass and an external weight

Notes on Using Data Memory

12.1.
To use the memory function, set the "Data memory (
"Time/Date output (
Table" for details on setting the data memory.
For weighing data, the data contents to be stored and the storage capacity depend
on the "Time/Date output (
If a different type of data exists in memory,
display to prompt you to delete the data.
For example: You want to store weighing data but calibration data or unit mass
data remains in memory.
If the stored data is corrupted,
Under such a condition, before storing data, delete the data in memory as follows:
Releasing "Clr" or "err"
1 Press and hold the
then release the key.
2 Press the
RE-ZERO
3 Press the
PRINT
4 The balance displays

Data Memory for Weighing Data

12.2.
Features
The balance can store 200 sets of weighing data in memory (if the time and date are added, the
balance can store 100 sets). Even if the AC adapter is removed, the data is maintained in the memory.
It is not necessary to connect a printer or personal computer to the balance continually, because
the balance stores the weighing data in memory.
The data memory function does not occupy a printer or personal computer while weighing.
The data in memory can be displayed on the balance for confirmation.
The data in memory can be output at one time to a printer or personal computer.
Comment: Select items for addition to the output data, such as the ID number, data number, time
and date, in the function settings.
BM series
Excluding the time and date
Including the time and date
Automatic self calibration
)" parameter of the function table. Refer to "10. Function
5-td
)" parameter setting.
5-td
blinks.
"Clr"
blinks in the upper left of the display.
"err"
key (for approx. 2 seconds) until
PRINT
key to display
key to delete all the data in memory.
and returns to the weighing mode.
end
)" parameter and the
data
blinks in the upper left of the
"Clr"
SClr " n " o
with
blinking.
Clr " g " o
"go"
65
Up to 200 sets
Up to 100 sets
Last 50 sets
Upper left of
the display
with
blinking is displayed,
"no"