20. Specifications

Weighing capacity
Maximum display
Minimum display
Repeatability
(Standard deviation)
Linearity
Stabilization time
(Typical at
FAST
Sensitivity drift
Operating environment
Display refresh rate
Environmental sensors Resolution: Temperature ±1.5 °C, Humidity ±10 %, Barometric pressure ±10 hPa
Minimum unit
mass
Number of
samples
Minimum 100%
reference mass
Minimum display
Interface
External calibration
weight
Size of loading area for
weighing mm
External dimensions
Power supply &
AC adapter type
Mass
The operating environment with no excessive changes in ambient temperature and humidity, no
vibration and drafts, no influence by magnetic fields and static electricity.
The internal mass may change due to corrosion or other damage caused by the operating environment,
or due to aging. Check the internal mass periodically and correct the internal mass value if necessary.
*1: Even when a tare weight beyond the precision range is placed, the weighing sample can be weighed in
the precision range if using the smart range.
*2: Repeatability using a 1 gram weight within the weighing capacity.
*3: Repeatability using a 100 gram weight within the weighing capacity.
BM-20
BM-22
22 g
22 g
22.00008 g
22.000084 g
5.100009 g
*1
0.01 mg
0.001 mg
0.001 mg
0.01 mg
0.0025 mg
*2
0.004 mg
*2
±0.02 mg
±0.010 mg
±0.010 mg
)
Approx. 10 seconds
±2 ppm/°C (10 °C to 30 °C, Automatic self calibration: OFF)
5 °C to 40 °C, 85 % RH or less (No condensation)
1 mg
0.01 %, 0.1 %, 1 % (Depends on the reference mass stored.)
20 g
10 g
5 g
2 g
1 g
Weighing pan: 25,
Filter weighing: 50, 95
Micro tube holder: 12
Power consumption: Approx. 30 VA (supplied to the AC adapter )
Confirm that the adapter type is correct for the local voltage and power
BM-252
250 g
5.1 g
250.00084 g 520.0084 g 320.0084 g 220.0084 g
0.01 mg
0.03 mg
*3
±0.10 mg
Approx. 8 seconds
5 times/second or 10 times/second
Applicable range: 5 °C to 40 °C
0.1 mg
10, 25, 50 or 100 pieces
USB and RS-232C
20 g
200 g
10 g
100 g
5 g
50 g
2 g
20 g
1 g
10 g
Weighing pan: 90
Micro tube holder: 12 (Option)
259(W) x 466(D) x 326(H) mm
receptacle type.
Approx. 10 kg
100
BM-500
BM-300
520 g
320 g
0.1 mg
0.2 mg
±0.5 mg
±0.3 mg
Approx. 3.5 seconds
10 mg
500 g
300 g
300 g
200 g
200 g
100 g
50 g
100 g
50 g
BM-200
220 g
0.1 mg
±0.2 mg
200 g
100 g
50 g
BM series