DIN/ISO programming | Feed rate, shaft speed
Feed per revolution Gx95
Gx95 defines a drive-dependent feed rate.
G95: Main spindle
Gx95: Spindle x (x: 1...3)
Parameters:
F: Feed per rot. in mm/rev or inch/rev
Example: G95, Gx95
. . .
N1 G14 Q0
N2 T3 G95 F0.25 G96 S200 M3
N3 G0 X0 Z2
N5 G1 Z0
N6 G1 X20 B-0.5
. . .
HEIDENHAIN | User's Manual smart.Turn and DIN Programming | 12/2017
4
299