General Settings - Calrec SUMMA User Manual

Networked audio production system
Hide thumbs Also See for SUMMA:
Table of Contents

Advertisement

GENERAL SETTINGS

To access Summa's general settings, ensure the touch display is in 'active Show' view and tap
in the top right of the screen and then select 'general settings' from the menu on the left hand side. To edit these
settings you must be logged in as an administrator.
General Settings
The following general settings are available:
The analogue level at 0 dBFS can be calibrated to 15, 18, 20, 22, 24 or 28 dBu.
The reference level (dBFS) can be set to an integer value between -6 and -32 dBFS. The reference level sets default
level values for the dynamics and oscillator modules.
The point at which the input impedance changes between mic and line level can be set to 18, 20, 22 or 24dBu.
The mic input headroom for the system can be chosen. Options range from 20 dB to 36 dB.
The default meter style can be set for all meters on the meter displays. PPM or VU scales can be chosen along with
various colour split points, controlling the level ranges of the green, yellow and red elements of the meter bar graphs.
Cut/on button functionality can be set: With cut selected, paths are cut when cut/on buttons are active; with
on selected, paths are switched on when the cut/on buttons are active, and so paths are cut when cut/on buttons are
not active.
If you have not routed the PFL bus to the console monitors, you can choose to route it to the small LS, rather than
using the dedicated PFL LS output.
When faders are under CSCP control, this can be overridden when the fader is touched; Summa's faders are
touch sensitive. This feature can also be disabled.
You can choose whether or not to report system status messages for the redundant core modules.
If you have chosen a Summa with 128 channels and no redundancy you should set this to OFF.