Assigning GPOs
1. Tap GPO in the window header and select the box in which the GPO port is installed.
2.
Tap FUNCTIONS in the window header and choose a function type from the list. Alternatively, tap FADER OPEN or
FADER ON and select the relevant I/O box for the port that you wish to control.
3. Tap to select a function or port on the left, tap to select a GPO port on the right and tap CONNECT.
FIGURE 4 - GPO
Moving a GPO Function
1. Tap a destination and tap MOVE in the window footer.
2. Select a new destination and tap MOVE again, or tap CANCEL to discard any changes.
Removing a Destination
1. Tap one or more destinations and tap REMOVE in the window footer.
2. Tap REMOVE again to confirm or tap CANCEL to discard any changes.
GPO signal type
In most cases, GPO signals are latching, causing relays to remain active for as long as the control is active. For example,
a relay controlled by a fader open function will remain active the entire time that fader is open. Assigning GPOs to be
controlled from the User Buttons changes their mode from latching to momentary so the relay is only activated as long as
the button is pressed.
Testing GPO Functioning
A TEST GPO button is available in the window footer to quickly manually trigger GPO signals for testing purposes.
To use this you must be logged in as an administrator.
CALREC
Putting Sound in the Picture
175