SC No.
Type
SC No.
Type
SC667-40
D
SC No.
Type
SC667-41
D
Error Name/Error Condition/Major Cause/Solution
The machine detects the Slave2 mode error when starting up, or recovery
from energy saver mode.
The following board defects (Parts implementation defect, solder scrap,
implemented parts defect, etc.);
• BCU
• Paper Transport IOB
1. Turn the main power OFF/ON.
2. Replace the Imaging IOB.
3. Reconnect the harness between BCU and Imaging IOB.
4. Replace the harness between BCU and Imaging IOB.
5. Replace the BCU.
Error Name/Error Condition/Major Cause/Solution
Macaron1 Mode Setting Error
The machine detects the Macaron1 mode error when starting up, or
recovery from energy saver mode.
The following board defects (Parts implementation defect, solder scrap,
implemented parts defect, etc.);
• BCU
• IPU
1. Turn the main power OFF/ON.
2. Replace the IPU.
3. Reconnect the harness between BCU and IPU.
4. Replace the harness between BCU and IPU.
5. Replace the BCU.
Error Name/Error Condition/Major Cause/Solution
Macaron2 Mode Setting Error
The machine detects the Macaron2 mode error when starting up, or
recovery from energy saver mode.
SC620-Service Call 620-689