6. Troubleshooting
No.
SC876-04
No.
SC876-05
No.
SC876-99
1042
Type
Error Name/Error Condition/Major Cause/Solution
D
Log Data Error 4
An error was detected in the handling of the log data at power on or
during machine operation.
• Log encryption key is disabled but the log data file is encrypted.
(NVRAM data corruption)
• Log encryption key is enabled but the log data file is not encrypted.
(NVRAM data corruption)
Initialize the HDD (SP5-832-004).
Type
Error Name/Error Condition/Major Cause/Solution
D
Log Data Error 5
An error was detected in the handling of the log data at power on or
during machine operation.
• Only the NV-RAM has been replaced with one previously used in
another machine.
• Only the HDD has been replaced with one previously used in
another machine.
• Attach the original NV-RAM.
• Attach the original HDD.
• With the configuration that caused the SC, initialize the HDD
(SP5-832-004).
Type
Error Name/Error Condition/Major Cause/Solution
D
Log Data Error 99
An error was detected in the handling of the log data at power on or
during machine operation.
Other causes
-